Warning: 1. Ensure personnel have been trained in the handling and proper use of batteries. Always wear the correct personal protection equipment (PPE) when handling batteries. 2. Battery maintenance checks should also be completed as part of your routine maintenance inspections. 3. Always wear the appropriate PPE when handling electrolyte. If splashed with electrolyte, immediately flush the affected area with clean water and seek medical advice. 4. Never add undiluted sulphuric acid to a battery. 5. Keep batteries upright to prevent electrolyte spillage. Electrolyte is a dilute sulphuric acid and is harmful to the skin. 6. Use tools with insulated handles when removing or fitting the battery. Never place tools or metal objects across the battery terminals. 7. During charging, the battery gives off explosive gases. Keep the battery in a well ventilated area and away from naked flames and sparks. Smoking is also prohibited. 8. Generator set batteries, by law, must not be disposed of with household waste. Batteries contain hazardous materials and in the charged state, each cell contains electrodes of lead metal (Pb) and lead (IV) dioxide (PbO2) in an electrolyte of about 33.5% w/w (6 Molar) sulphuric acid (H2SO4). In the discharged state both electrodes turn into lead (II) sulphate (PbSO4) and the electrolyte loses its dissolved sulphuric acid and becomes primarily water.It can be damaging to the environment to send these to landfill, burning batteries can also cause atmospheric pollution.Dealing with lead acid batteries can be hazardous so it is important to follow all safety guidelines. Batteries are an essential part of the generator set and should be maintained appropriately. Keep the battery area clean and dry and ensure any vent caps are tight (if fitted). Clean the battery case with one of the following cleaning solutions: • A mixture of 0.1 kg (0.2 lb) of baking soda and 1 L (1 qt) of clean water • A mixture of 0.1 L (0.11 qt) of ammonia and 1 L (1 qt) of clean water Thoroughly rinse the battery case with clean water. All battery connections must be kept clean and tight. Use a fine grade of sandpaper to clean the terminals and the cable clamps.Clean the items until the surfaces are bright or shiny. Do not remove material excessively. Excessive removal of material can terminal protector to prevent corrosion. The electrolyte level should be covering the plates/grids (1/2 inch / 13 mm) within the battery to maximize full charge transfer. If the liquid level is below the plates/grids, only add distilled water; never add battery acid to top up the volume, as the addition of extra acid will destroy the grids. It is recommended to check the electrolyte and condition of the batteries every 500 running hours. In high ambient conditions, it is recommended to use thermal compensation and check electrolyte levels more frequently, for example every 200 running hours. These checks should also be completed as p...

Neutral-Earth Link (NEL) for a generator set

2018-09-28 16:24:53

Before the generator set is operated please consult your local dealer to establish whether an NEL has been fitted.

As more than one NEL per site may be unsafe, it is important to establish whether one has already been installed on site.

Depending on the specific product installation, a Neutral-Earth Link may be required on your generator set. Your local dealer or qualified electrical personnel should be consulted to confirm specific earthing requirements for the generator set installation, and to ensure that local wiring regulations are met.Safe and efficient operation of electrical equipment can be achieved only if the equipment is correctly operated and maintaine.Ensure the generator set, including a mobile set, is effectively grounded/earthed prior to operation.Do not touch electrically energised parts of the generator set and/or interconnecting cables or conductors with any part of the body or with any non insulated conductive object. Use only Class BC or Class ABC extinguishers on electrical fires.I For generator sets with external socket outlets only – Residual Current Device (RCD) protection on socket outlets,where fitted, is designed to operate within a TN earthing system. Ensure local wiring regulations are met priorto generator set operation and that all equipment connected via the generator set sockets, including plugs andelectrical cables, are of the correct specification and are known to be in a safe and undamaged condition.


Related reading: Cummins Generator Sets, Ricardo Generator Set

 
Got Free Inquiry Now Please click here for inquiry
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!