Warning:
2018-10-22

Warning:

Warning: 1. Ensure personnel have been trained in the handling and proper use of batteries. Always wear the correct personal protection equipment (PPE) when handling batteries. 2. Battery maintenance checks should also be completed as part of your routine maintenance inspections. 3. Always wear the appropriate PPE when handling electrolyte. If splashed with electrolyte, immediately flush the affected area with clean water and seek medical advice. 4. Never add undiluted sulphuric acid to a battery. 5. Keep batteries upright to prevent electrolyte spillage. Electrolyte is a dilute sulphuric acid and is harmful to the skin. 6. Use tools with insulated handles when removing or fitting the battery. Never place tools or metal objects across the battery terminals. 7. During charging, the battery gives off explosive gases. Keep the battery in a well ventilated area and away from naked flames and sparks. Smoking is also prohibited. 8. Generator set batteries, by law, must not be disposed of with household waste. Batteries contain hazardous materials and in the charged state, each cell contains electrodes of lead metal (Pb) and lead (IV) dioxide (PbO2) in an electrolyte of about 33.5% w/w (6 Molar) sulphuric acid (H2SO4). In the discharged state both electrodes turn into lead (II) sulphate (PbSO4) and the electrolyte loses its dissolved sulphuric acid and becomes primarily water.It can be damaging to the environment to send these to landfill, burning batteries can also cause atmospheric pollution.Dealing with lead acid batteries can be hazardous so it is important to follow all safety guidelines. Batteries are an essential part of the generator set and should be maintained appropriately. Keep the battery area clean and dry and ensure any vent caps are tight (if fitted). Clean the battery case with one of the following cleaning solutions: • A mixture of 0.1 kg (0.2 lb) of baking soda and 1 L (1 qt) of clean water • A mixture of 0.1 L (0.11 qt) of ammonia and 1 L (1 qt) of clean water Thoroughly rinse the battery case with clean water. All battery connections must be kept clean and tight. Use a fine grade of sandpaper to clean the terminals and the cable clamps.Clean the items until the surfaces are bright or shiny. Do not remove material excessively. Excessive removal of material can terminal protector to prevent corrosion. The electrolyte level should be covering the plates/grids (1/2 inch / 13 mm) within the battery to maximize full charge transfer. If the liquid level is below the plates/grids, only add distilled water; never add battery acid to top up the volume, as the addition of extra acid will destroy the grids. It is recommended to check the electrolyte and condition of the batteries every 500 running hours. In high ambient conditions, it is recommended to use thermal compensation and check electrolyte levels more frequently, for example every 200 running hours. These checks should also be completed as p...

  • Neutral-Earth Link (NEL) for a generator set

    2018-09-28

    Before the generator set is operated please consult your local dealer to establish whether an NEL has been fitted. As more than one NEL per site may be unsafe, it is important to establish whether one has already been installed on site. Depending on the specific product installation, a Neutral-Earth Link may be required on your generator set. Your local dealer or qualified electrical personnel sho...

  • Control System Of A Gensets

    2018-10-08

    An electronic control system has been designed and installed to control and monitor the generator set. Depending on the requirements of the Diesel generator set, one of several different standard control systems may be fitted. Other more specialised systems may be fitted for specific installations in which case separate documentation is provided.These control systems consist of three major compone...

  • Generator Control System Description

    2018-10-08

    An electronic control system has been designed and installed to control and monitor the generator set. Depending on the requirements of the generator set, one of several different standard control systems may be fitted. Other more specialised systems may be fitted for specific installations in which case separate documentation is provided. These control systems consist of three major components wo...

  • Generator Pre-Start Checks

    2018-10-08

    The following checks detailed below are the only tasks that an operator should undertake. The following checks should be performed prior to starting the generator set: 1. Ensure the Control Switch / Key Switch is Off. A visual inspection should take only a few minutes and can prevent costly repairs and accidents – For maximum generator set life, visually inspect the generator set before starting. ...

  • Trouble Shooting Guide For Diesel Generator

    2018-11-07

  • Batteries Maintenance For Generator Set

    2018-10-19

    Warning: 1. Ensure personnel have been trained in the handling and proper use of batteries. Always wear the correct personal protection equipment (PPE) when handling batteries. 2. Battery maintenance checks should also be completed as part of your routine maintenance inspections. 3. Always wear the appropriate PPE when handling electrolyte. If splashed with electrolyte, immediately flush the affec...

  • Genset Battery Removal and Fitting

    2018-10-31

    •Battery acid can burn clothing and skin or cause blindness if it leaks. Please wear protective clothing when inspecting a battery prior to its disconnection / transportation. • Ensure the battery to be fitted is filled with the correct levels and mixture of electrolyte and is fully charged. • If vents are fitted, ensure they are firmly in place. • Before removing a battery, carry out a thorough i...

  • manipulation of the gensets

    2018-12-27

    4.1 If the engine is on bacic of cold starting,please idle it for 5 minutes without any load;if the engine is on basic of warm starting,please load after oil pressure is established;please steadily speed up and load after water temperature rises up to60℃. 4.2 Please keep a 50-hours breaking-in or running-in period if it a new engine or an engine just after an overhaul. 4.3 At high speed,the oil pr...